    What’s A Bubbler

    Installation Tips, Plumbing, Troubleshooting

    Prison combination toilet bubblers serve double duty as a sink faucet and drinking fountain — which is why they must be installed with the outlet facing up. A repeat offender of TICI violations had to completely uninstall every fixture to flip one screw on the back of each bubbler.

  • Placeholder image with Axiom logo

    Small Squirrel Cage Fans

    Motors & Electrical, Troubleshooting, Ventilation

    When small rooftop units came up short on airflow, the fix was surprisingly simple: swap in the next-size-up motor. The same fan with a higher-horsepower motor runs at a slightly higher RPM due to less slip, producing enough additional airflow to satisfy the balancer.

  • Placeholder image with Axiom logo

    Garbage In, Garbage Out

    Controls & Thermostats, Pumps & Circulators, Troubleshooting, Variable Speed

    Pressure-independent control valves were being blamed for a building's pumps running at 80% speed regardless of load. The real problem was the differential pressure sensor installed right at the pumps instead of out in the system — feeding garbage information to the variable speed pump controller.

  • Placeholder image with Axiom logo

    One Too Many Strainers

    Heat Exchangers, Strainers & Filtration, Troubleshooting

    A radiant floor system isolated by a flat plate heat exchanger wasn't working because the PHE had become plugged with pebbles and debris. Two strainers were installed downstream of the exchanger instead of upstream — protecting nothing. A reminder to always put strainers where they'll actually do some good.

  • Placeholder image with Axiom logo

    New Project, Old Spec

    Industry Commentary, Specifications & Standards, Steam Systems

    Outdated specifications can create real headaches. A hospital steam project's submittal was rejected because the spec called for bucket traps — even though the thermodynamic traps already installed were the superior choice for high-pressure drip applications. Even the competitor's own selector guide agreed.

  • Placeholder image with Axiom logo

    Fine Print On Boiler Control

    Boilers, Controls & Thermostats, Troubleshooting

    A modulating-condensing boiler connected to a radiant garage slab was short-cycling badly despite being properly set up. The culprit was hidden in the manual's fine print: the controller was adding 10°F to whatever operating differential temperature was entered, causing the burner to overshoot and cycle repeatedly.

  • Placeholder image with Axiom logo

    Air Separator: The Missing Link

    Air Management, Best Practices, Hydronic Design

    Of the essential components every modern hydronic system needs, the air separator is the one most often missing. Without one, automatic air vents won't work properly, and the result is noise, poor circulation, and poor heat transfer. High temperature, low pressure, and low water velocity are the keys to effective air separation.

  • Placeholder image with Axiom logo

    I Thought It Looked Better

    Installation Tips, Pumps & Circulators, Troubleshooting

    When a wet rotor circulator pump failed to operate on a radiant floor heating project, the culprit was simple: the pump had been installed with the motor shaft vertical because the installer thought it looked better. All wet rotor pumps must be installed with the shaft horizontal, as the bearings aren't designed for thrust loads.

  • Placeholder image with Axiom logo

    Schlembe

    Heating Systems, Hydronic Design, Troubleshooting

    Albert Einstein's word 'schlembe' — an improvement that makes things worse — perfectly describes what happened when an energy performance upgrade left a school freezing. Incorrectly installed monoflo tees and added control valve head loss combined with a revised ventilation schedule to kneecap the heating system.

  • Placeholder image with Axiom logo

    Where is the Water Going?

    Balancing, Hydronic Design, Troubleshooting

    A 15-storey apartment building with chronic cold complaints had most of its pump flow short-circuiting through an oversized, unbalanced unit heater in the penthouse mechanical room. Closing one ball valve brought immediate improvement — and a tenant confirmed the problem had existed for 22 years.